Monitoring and response
The checked-in Prometheus configuration and alert rules provide an initial availability alert. They need an existing Prometheus instance and an operator responsible for its notifications. The files do not install a monitoring service, configure a notification destination or grant anyone access to Debuglet.
Configure a collector
Section titled “Configure a collector”- Copy the example and rules into your Prometheus configuration directory.
Set the actual dispatcher HTTPS address and its trusted CA. Keep the job name
debuglet-dispatcher, which the rules select explicitly. - Use a dedicated operator account. Store its session in the file named by
authorization.credentials_file, readable only by the collector identity; refresh it before expiry. Never store the token in Git, command-line arguments, a target URL or alert labels. An expired or revoked session makes the scrape fail and fires the availability alert. - Run
promtool check config prometheus.ymlandpromtool test rules alerts.test.yml health-alerts.test.ymlbefore reloading. The repository records the tested Prometheus version and archive checksum in prometheus-version.env. - Route
owner=debuglet-operatorto the team’s existing on-call destination in Alertmanager. The deploying team must choose the actual person or rotation. Verify receipt using that system’s existing notification test. The local drill below verifies firing/resolution, not external message delivery.
Every configured target is evaluated independently. The absent(up) condition
also catches a completely missing job. Removing one target from a multi-target
job removes its monitoring; retain and review the intended target inventory.
Prometheus itself needs independent monitoring: it cannot send an alert while
its own process or notification route is down.
Availability
Section titled “Availability”DebugletUnavailable fires when the scrape fails or a required observation is
missing, API admission readiness fails, or no currently eligible executor has
positive advertised bandwidth. It also refuses a control observation more than
45 seconds away from the collector’s wall clock. Synchronize those hosts’ clocks;
a clock discrepancy is a diagnostic condition, not evidence of readiness.
Defaults are 15-second scrape and evaluation intervals, a five-second scrape timeout and a 45-second pending period. The conservative observation budget is 90 seconds after the failure becomes authoritative. Silent network loss can first require expiry of the dispatcher’s configured control lease (normally 60 seconds); add that lease interval to the failure-to-alert budget. An immediate control disconnect does not need that grace period. These are initial operating thresholds, not an availability SLA.
Recovery clears the condition after a successful scrape and rule evaluation (normally within 30 seconds, allowing the one-second metrics cache). The alert checks readiness and positive advertised capacity before reservations. It is not proof that a requested bandwidth/window/destination can be admitted.
When it fires:
- Inspect Prometheus’s target error first. Distinguish an expired collector session or CA/network failure from an unavailable dispatcher.
- Read
/healthz,/readyz,/healthand authenticated/metrics. A live dispatcher can have zero eligible executors. Heartbeat telemetry does not renew the authority of an expired executor control session. - On a managed host run
dbl --output json service status --role dispatcherand the corresponding executor status. For a foreground role, inspect its launcher and daemon log in that role’s state directory. - With the operator CLI installed, run
dbl --endpoint https://dispatcher.example --timeout 10s --output json doctor --connection. On the daemon host, rundbl --output json doctor --role executor --file /etc/debuglet/executor/executor.tomlas the service identity. Check configuration, permissions, available storage and capability mode. Doctor’s invoking process is not proof that a differently sandboxed service has the same permissions. Do not add--offlineto a running database check: stop its writer first. Releases withoutdoctorneed the operator CLI update before using this part of the runbook. - Correct the diagnosed configuration, credential, resource or transport problem, then restart/resume only the affected role. Confirm a new available control session and positive capacity, and inspect the metrics observation timestamp.
- Inspect retained run states and
debuglet_retained_runs_unknownafterward. Reconnection and alert resolution do not replay lost work or change an unknown outcome into success. Resubmit only through the normal application decision.
Do not repair an availability alert by deleting the database, journals, WAL files, executor identity or active package directory. Keep stopped state and logs for diagnosis; use the documented upgrade/recovery operations where needed.
Executor health
Section titled “Executor health”Enable health-alerts.yml alongside the
availability rule. These rules use the same 45-second pending period and refuse
missing, failed or stale observations. The executor’s capability report expires
after 90 seconds without refresh; allow that additional interval for a silent
reporting failure. Test their controlled failure/recovery fixtures with
promtool test rules deploy/monitoring/health-alerts.test.yml.
DebugletRequiredCounterUnavailable is opt-in: set the collector target label
require_ebpf: "true" only when every registered executor is required to select
eBPF with its owned ingress and egress TCX links present. Otherwise a supported
fallback does not raise this alert. The rule fires when any selection is
fallback/unknown, either attachment is missing/unknown, or observations cannot
be collected. Recovery requires a fresh positive attachment report from every
registered executor, so old executors without this observation remain unknown.
This is a collector policy, not a new executor enforcement setting. Attachment
presence does not verify packet coverage, accounting or effective policing.
Allow the 30-second report cadence before the normal scrape/evaluation budget;
silent report loss can instead take the 90-second report expiry above.
DebugletDisclosureUnhealthy fires when any registered executor reports failed
key refresh, an excessive disclosure hold, an exhausted/not-yet-started signing
chain, an expired announced schedule or unknown state, or when the dispatcher’s
disclosure delivery lag exceeds 90 seconds or is unknown. It remains firing when
an unhealthy report expires or the lag sample is missing. Resolution requires
fresh positive subsystem reports, unexpired schedules and a known lag of at most
90 seconds for every executor; a heartbeat alone is insufficient. The lag counts
only keys this dispatcher verified and recorded in its database; it does not
validate captured tags.
The 90-second lag threshold is three maximal heartbeat intervals (an executor discloses on every heartbeat, at most 30 seconds apart) and equals the report lifetime above, so one or two lost heartbeats do not alert. Until the first disclosure of a chain reaches a dispatcher process, for example after either daemon restarts, the lag is unknown for up to one heartbeat once a key is due; the pending period normally covers that.
DebugletExecutorStateStorageLow fires below 10% available space on any executor
state filesystem, or when the aggregate is incomplete. It uses each executor’s
available/capacity ratio rather than dividing unrelated extrema. RSS and FD
metrics describe the executor daemon, excluding guest workers; set thresholds
suited to your service limits using host monitoring for the whole service.
When an executor health alert fires:
- Use the operator executor listing to identify the affected executor and its capability, attribution and clock fields; metrics intentionally omit its ID.
- For fallback, inspect
enforcement_reasonand daemon logs. Check the service’s configured interface and permitted capabilities.configuredis deliberate;not_permitted,unsupportedandattach_failedrequire different repairs. Do not grant broad privileges or switch off a required policy just to clear an alert. - For failed refresh or held disclosure, inspect the executor’s tagger errors and clock state. Drain affected work before repairing/restarting the service; preserve its identity, database and logs. Do not manually disclose a key that a kernel slot might still use, or treat a reconnect as cleanup evidence.
- For disclosure lag, compare the executor’s disclosure hold and its
next_disclosure_epoch(GET /executors/:id/tesla) with the dispatcher log. A rejected or early disclosure is logged once per chain; a failed database write is retried with the next disclosure. Check the control session and the dispatcher’s database before restarting the executor, which starts a new chain. - For chain exhaustion, stop admission and follow the daemon’s logged
final_disclosure_atbefore restart. Increase the next chain’s configured lifetime if needed. An early restart can lose disclosure of its final epochs. - For a missing attachment, inspect the configured interface and the service’s owned TCX links. Drain and repair/restart the affected service; this observer does not reattach programs. Preserve its identity and state. A fresh selection alone cannot clear the alert; both attachment observations must recover.
- For storage pressure, inspect each executor’s database filesystem and recover space without removing active state, identity, journals or guest output. Confirm a fresh complete ratio above the threshold. Missing measurements do not establish recovery.
- Confirm new reports show the intended counter, present attachments, available attribution, positive remaining lifetime and a known disclosure lag. Validate traffic separately when claiming enforcement or attribution. Alert resolution does not repair historical runs.
These rules monitor the current registry. Removing a failed executor can clear its aggregate condition; it does not prove that host recovered. Maintain the expected executor inventory separately. The availability rule covers a missing scrape job; retain it rather than using these health rules alone.
Local drill
Section titled “Local drill”Run only in an owned disposable Linux container with its own network namespace;
no host network and no external endpoint. It needs Python 3, a full installed
Debuglet package containing /metrics and debuglet_api_ready, the pinned
Prometheus executable, and the existing examples/debuglets/go/loop guest built
for WASI. It creates new local dispatcher/executor state and an operator session,
scrapes with that session from a private file, submits a running guest, abruptly
stops only verified child daemons and restarts them.
promtool check rules deploy/monitoring/alerts.ymlpromtool test rules deploy/monitoring/alerts.test.ymlGOOS=wasip1 GOARCH=wasm go build -o /tmp/alert-loop.wasm ./examples/debuglets/go/looppython3 deploy/monitoring/drill.py \ --install-root /tmp/debuglet-install \ --prometheus /tmp/prometheus/prometheus \ --loop-wasm /tmp/alert-loop.wasmThe report checks executor control loss while dispatcher liveness remains true, a dispatcher outage, both alert resolutions within the configured budget, and a retained nonterminal/unknown result after recovery. The fixture uses the explicit loopback development profile, not a production TLS deployment. It supplies a real operator credential but does not validate external provisioning or notification routing. A successful drill joins children and removes its private state. On failure it prints the retained private diagnostic directory; remove the owned container after inspection.
Storage and backups
Section titled “Storage and backups”Enable storage-alerts.yml and the
backup scrape when operating
the supported offline backup profile. DebugletStateStorageLow checks the
dispatcher’s state filesystem, firing below 10% space available to
unprivileged writes, or when that observation is missing. This does not cover
executor disks (use the executor health rule above), filesystem quotas or inode exhaustion; retain host monitoring
for those. A failed dispatcher scrape is covered by DebugletUnavailable.
Backups currently require a clean, joined foreground shutdown and --offline.
They do not cover running systemd services or independently started daemons.
Use a package providing the installed dbl backup command; the wrapper does not
make an unsupported state directory safe to copy. It does not stop services or
schedule backups. Schedule a supported offline maintenance window at least daily
if using the default 24-hour freshness threshold; choose a different documented
threshold when your recovery objective requires one.
Use an existing node_exporter textfile collector on the same host as Prometheus, listening on loopback. The tested version/checksum is in node-exporter-version.env. Create a dedicated textfile directory owned by the backup identity, readable by the collector, and not writable by any other user. For example:
node_exporter --web.listen-address=127.0.0.1:9100 \ --collector.textfile.directory=/var/lib/debuglet-backup-metricspython3 deploy/monitoring/backup-metrics.py \ --dbl /opt/debuglet/bin/dbl --state-dir /srv/debuglet-stopped \ --destination /srv/backups/debuglet-20260928 \ --metrics-file /var/lib/debuglet-backup-metrics/backup.prom --offlineChoose a new destination each time. This configuration monitors one backup
state directory per collector target; do not publish duplicate metric names from
multiple profiles into the same textfile collector. Keep the actual backup directory private;
the .prom file contains only fixed numeric outcomes and timestamps, never
credentials, identities or paths. The wrapper serializes its own invocations,
runs the installed command with a five-minute timeout, and accepts success only
after exit zero plus a matching published backup manifest. The installed command
owns SQLite, schema and inventory verification. The wrapper never inspects the
credential payload or treats a directory’s mtime as proof of a valid backup.
DebugletBackupFailed fires on a failed last completed attempt, missing result,
failed scrape or textfile parsing error. DebugletBackupStale fires when there is
no verified backup, its completion is over 24 hours old, or its timestamp is in
the future. Failed or malformed output preserves the previous verified timestamp.
Killing the wrapper cannot advance success; freshness will still expire even if
that abrupt termination prevented recording a completed failure. These are
last completed attempt metrics, not proof that a backup is currently running.
Use the same 15-second collection/evaluation and 45-second pending period as the
availability rules; the conservative observation budget is 90 seconds.
When storage or backup alerts fire:
- Inspect collector errors and the last completed result first. Check capacity, permissions, quota/inodes, package compatibility and whether the foreground writer really joined before invoking backup. Preserve the failed destination for diagnosis; retry into a fresh destination.
- Recover space by expanding the filesystem or moving verified, inactive backup copies according to retention policy. Never delete the active installation, state database, WAL/journal/SHM sidecars, executor identity or an in-progress backup to silence an alert.
- Complete a new verified backup. Confirm both backup alerts clear and the verified timestamp advances; periodically exercise documented restore into a fresh state directory. A green backup alert alone is not a restore drill.
For the owned storage drill, provide a dedicated 64 MiB tmpfs at /pressure
inside a disposable container (--tmpfs /pressure:size=64m,mode=700, no host
network or published ports). Keep Prometheus data outside that tmpfs. The script
refuses non-tmpfs or filesystems over 128 MiB and creates its own state directory.
python3 -m unittest discover -s deploy/monitoring -p '*_test.py'promtool test rules deploy/monitoring/storage-alerts.test.ymlpython3 deploy/monitoring/storage-drill.py \ --install-root /tmp/debuglet-install \ --backup-install-root /tmp/debuglet-backup-install \ --prometheus /tmp/prometheus/prometheus \ --node-exporter /tmp/node_exporter/node_exporter --pressure-dir /pressureThe two installed roots may be the same version once both capabilities are included. The drill measures an actual low-space alert, removes only its filler file, checks a missing-backup alert, makes an installed verified offline backup, injects a failed attempt using an existing destination, and verifies that a new successful backup resolves both failure and freshness. Rule tests separately advance synthetic time to cover expiration and future timestamps. No external notification delivery is claimed.